HOME > Products > Solar & Wind > SLU Series 800W~8000W > PM-0800SLU



Certificate
On-line Catalog


Front Panel
Back Panel
LCD Display
Character:
LCD display
Solar charge controller
Multistage charger
Fast Action AC Synchronized Transfer Switch
Microprocessor based design
Heat-Sink built in internal
Soft Start
AVR design
Input & Output isolated
Auto temperature control fan
Reverse polarity protection. / by fuse / diodes /
Output short circuit protection
Temperature protection
Overload protection
Input low voltage protection
Input high voltage protection
Low battery alarm
Low battery shut-down

Description:
Solar Inverter with LCD Display~
PURE SINE WAVE Inverter with DC battery charger and Solar charge controller
Connect directly with Solar system
Smart, powerful and successful


Specifications:

Model No.

PM-800SLU-12

  Output Power Continuous

800W

  Max. Surge Power

1600W

1. Input Section 

  Input Nominal Voltage

120Vac or 220Vac

  Input Voltage Range

60V~135Vac or 120V~270Vac

  Line Low Transfer

60Vac +/- 2% or 120Vac +/- 2%

  Line Low Return

65Vac +/- 2% or 130Vac +/- 2%

  Line High Transfer

135Vac +/- 2% or 270Vac +/- 2%

  Line High Return

130Vac +/- 2% or 260Vac +/- 2%

  Input Frequency

Auto 50Hz/60Hz (45Hz~75Hz)

2. Output Section

  Output Voltage

110Vac / 115Vac / 120Vac or 220Vac / 230Vac / 240Vac re-settable via LCD panel

  Waveform

Pure Sine Wave

  Voltage Regulation (Batt. Mode)

< 3% RMS for entire battery voltage range

  Output Frequency

ADJ. 50Hz or 60Hz +/- 0.1Hz

  Total Harmonic Distortion Output THD

< 3%

  Maximum Load

Up to short circuit

  Asymmetrical Load Max.

Up to nominal output power

  Overload and Short Circuit Protection

Automatic disconnection

  Overheating Temperature Protection

Acoustic warning before shut-off. Automatic restart

  Power Factor

0.8

  LCD Display

UPS status, I/P&O/P Voltage Frequency, Load%,Battery Voltage & %, Temperature, Model

  LED Display

Normal (Green), Warning (Yellow), Fault (Red)

  Maximum Efficiency

85~92%

3. Battery Section

  Voltage Range

12VDC (10~16VDC)

  Backup Time (at full load)

Long time available

  Input Frequency Range

45~70Hz

  Max. Charging Current
  (3 steps selectable)

>40Amp

4. Solar Charge Regulator-Floating

  Maximum Open Circuit Voltage

55V

  Maximum Charging Current

50A (Optional)
5. Audible Alarm

  Battery Mode

Beeping every 4 seconds

  Low Battery

Beeping every second

  Solar Inverter Fault

Beeping continuously

  Overload

Beeping twice per second

  Temperature Compensation (Option)

3mV / cell

6. General date

  AC By Pass Time (UPS Mode)

<10ms max

  Operation Temperature

-20 to +55

  Max Current at Transfer Relay

40A / AC 220V

  Audible Noise

Less than 55dBA (at 1M)

  Relative Humidity

0-95% non-condensing

  Accessory

 

  Dimensions (L x W x H mm)

 

  Net Weight (by Kg/s)