| MODEL NO. |
12 Volt System
24 Volt System
48 Volt System |
PM-1500SSL-12X(1)
PM-1500SSL-24X
PM-1500SSL-48X |
PM-3000SSL-12X(1)
PM-3000SSL-24X
PM-3000SSL-48X |
| GENERAL |
| Ventilation |
Forced cooling |
Forced cooling |
Temperature
|
Operation
Storage |
-20°C ~ +70°C
-25°C ~ +80°C |
-20°C ~ +70°C
-25°C ~ +80°C |
| Protection |
|
|
| |
a. Output short circuit |
∨ |
∨ |
| |
b. Over load |
∨ |
∨ |
| |
c. Battery voltage too high |
∨ |
∨ |
| |
d. Battery voltage too low |
∨ |
∨ |
| |
e. DC voltage ripple too high |
∨ |
∨ |
| |
f. Temperature Sensor |
|
|
| |
Transformer |
∨(105°C) |
∨(105°C) |
| |
Electronic & Powerstage |
∨(70°C) |
∨(70°C) |
| |
BTS-3 |
∨(50°C) |
∨(50°C) |
| Humidity |
0~95% (non condensing) |
0~95% (non condensing) |
| Power control Function |
∨ |
∨ |
| Power assist Function |
∨ |
∨ |
| Uninterrupted AC power |
∨(less than 10 msec) |
∨(less than 10 msec) |
| Adaptive 4-stage charge |
∨ |
∨ |
| Two output to charge 2 battery banks |
∨ |
∨ |
| Auxiliary Relay |
X 3 |
X 3 |
| Battery voltage sensor |
∨ |
∨ |
| Battery Temperature sensor (BTS-3) |
∨ |
∨ |
| Remote control port |
∨ |
∨ |
| INVERTER |
| Input Voltage Range (VDC) |
9.5~16V / 19~32V / 38~64V |
| Output Voltage (VAC) |
185~240 VAC / 90~120 VAC |
| Output Frequency |
50Hz / 60Hz ± 0.1% |
| Output Waveform |
Pure sinewave |
| Output Voltage THD |
< 5% |
| Power Factor (All Loads) |
∨ |
| No linger load, crest factor |
3 : 1 |
Cont. Power Output (W)
Under 70°C (cosθ=1.0) |
1500W
(No derate) |
3000W
(No derate) |
Cont. Power Output (W)
Over 70°C (cosθ=1.0) |
0W
(Shutdown) |
0W
(Shutdown) |
| Maximum Power (W) |
3000W |
6000W |
| Maximum Efficiency (%) |
82/84/85 |
84/86/89 |
| Zero-load Power (W) |
12W |
18W |
| CHARGER |
| Input Voltage Range (VAC) |
200~250 VAC / 100~125 VAC |
| Input Frequency |
45-55Hz / 55-65 Hz |
| Power Factor |
1 |
| Charge Characteristic |
4-stage adaptive / Bulk-Absorption-Float-Equalize |
| Maximum DC Voltage Ripple (Vrms) |
< 1.25 V |
| Charge Current House Battery (A) |
70A/40A/20A |
140A/70A/40A |
| Charge Current Starter Battery (A) |
4A |
| Absorption Voltage Default (VDC) |
14.4V / 28.8V / 57.6V |
| Float voltage Default (VDC) |
13.8V / 27.6V / 55.2V |
| Equalize Voltage default (VDC) |
13.2V / 26.4V / 52.8V |
| Output Charge Voltage (min ~ max) |
8V~16V / 11V~32V / 22V~64V |
| Battery Temperature sensor |
BTS-3 |
| SOLAR CHARGE |
| System voltage ratings |
12, 24, 48 Vdc |
| Current ratings-Battery Charge Control |
40A |
| Accuracy |
12/24V:≤0.1 % ± 50 mV
48V:≤0.1 % ± 100 mV |
| Min. voltage to operate |
9V |
| Max. solar array Voc |
140V |
| Max. operating voltage |
68V |
| Total current consumption |
While operating -25mA, at idle -3mA |
| High temp shutdown |
90°C disconnect solar
70°C reconnect solar |
| Transient surge protection |
| |
pulse power rating |
4500 watts |
| |
Response |
< 5 nanosec |
| ENVIRONMENTAL |
| Ambient temperature |
-40 to +45°C |
| Storage temperature |
-55 to +85°C |
| Humidity |
100% (NC) |
| AC INPUT SWITCH |
| AC IN Terminal Circuit Breaker |
30A (110V) /15A (220V) |
60A (110V) /30A (220V) |
| Switch-over Time |
|
| |
a. inverter to AC input |
0 msec. |
| |
b. AC input to inverter |
0 msec. |
| Detection Time AC Input Fault |
4 ~10 msec. |
| Trip Level AC Input to Inverter |
90 VAC / 180 VAC |
| Trip Level Inverter to AC Input |
94 VAC / 187 VAC |
| Min.~ Max. Frequency Range |
45-55 Hz / 55-65 Hz |
| MECHANICAL |
| Cabinet / Protecting Class |
Aluminum / IP20 |
| Dimension (H X W X D) |
Wall: 298 x 256 x 368
Table: 189 x 285 x 494 (mm) |
Wall: 355 x 256 x 368
Table: 189 x 285 x 708 (mm) |
| Weight (kgs) |
30 kgs |
35 kgs |
(1) X should be 1, output voltage = 90~120 VAC or 2, output voltage = 185~240 VAC