Power Inverter with Solar Charger
Enlargement
Product Name : PM-1600SLU
Inquiry
Product Description

Character:
Multiple microprocessor design base.
Compatible with both linear & non-linear load.
Stronger charger to support batteries of 600AH up.
24 hours operation on the inverter.
DC start and automatic self-diagnostic function.
THD less than 3%.
High efficiency design to save electricity.
Low heat dissipation in long time operation.
Design to operate under harsh environment.
3U 19" Rack Mount or WALL Mounted design.
DC priority or AC priority selectable.
Support solar panel.

Description:
Solar Inverter with LCD Display~
PURE SINE WAVE Inverter with DC battery charger and Solar charge controller.
Connect directly with Solar system.
Smart; powerful and successful.


Specifications:

Model PM-1600SLU-24
Capacity VA / Watt 2.4KVA / 1600W
Input Nominal Voltage 220Vac ; 110Vac
Voltage Range Acceptable Voltage Range 120-280Vac ; 60-140Vac
Frequency 50Hz / 60Hz ( 45Hz - 70Hz)
Line Low Transfer 120VAC ± 2% ; 60VAC ± 2%
Line Low Return 130VAC ± 2% ; 65VAC ± 2%
Line High Transfer 280VAC ± 2% ; 140VAC ± 2%
Line High Return 260VAC ± 2% ; 130VAC ± 2%
Output Voltage 200 / 220 / 230 / 240Vac (re-settable via LCD panel)
100 / 110 / 115 / 120Vac (re-settable via LCD panel)
Voltage Regulation (Batt. Mode) < 3% RMS for entire battery voltage range
Frequency 50Hz or 60Hz
Frequency Regulation (Batt. Mode) ± 0.1Hz
Power Factor 0.67
Waveform Pure Sinewave
Effiecincy > 80%
Overload Protection Line Mode Circuit Breaker
Battery Mode 110% ~ 150% for 30 sec. ; >150% for 200ms
Transfer Time Typical < 8 ms.
Battery Battery Voltage 24Vdc (20~32)
Backup Time (at full load) long time available
Max. Charging Current
(3 steps selectable)
60 / 80 / 100 Amp
Solar Charge Battery Voltage 24V
Charge Voltage 27.7V
Solar Maximum Peak Voltage 50.0V
Solar Charge Working Voltage 24.0V
Maximum Charging Current 50A
Polarity Protect YES
Back Flow Protect YES
Display LCD LCD UPS status; I/P&O/P Voltage Frequency; Load%;
Battery Voltage & %; Charge current; Temperature;
Model
LED Normal (Green); Warning (Yellow); Fault (Red)
Audible
Alarm
Battery Mode Beeping every 4 seconds
Low Battery Beeping every second
UPS Fault Beeping Continuously
Overload Beeping twice per second
Environment Operation Temperature 0-40 °C ; 32-104 °F
Relative Humidity 0-95% non-dondensing
Audible Noise Less than 55dBA (at 1M)
Physical Net Weigh (Kgs) 21
(WxHxD) mm Black Case 298 x 450 x 150
(WxHxD) mm Rack Mount 440 x 132 x 360
(WxHxD) mm Wall Mounted 298 x 450 x 190