HOME > Products > UPS > Heaven Series (Rack Mount) 0.6K~3.0KVA > PM-321500SKC

無標題文件


Certificate
On-line Catalog
Back Panel
Character:
Line interactive design
Boost and buck AVR
Hot swappable battery replacement by users
Overload, on-line, battery status LED or LCD display
Fully digitized microprocessor controlled
Smart RS-232 communication port
Lightning and surge protection
Short circuit and overload protection
50/60Hz frequency auto sensing
Tel/modem internet spike protection
Site wiring fault warning *
Smart power management with software
Load/Battery power meter display
Advanced battery management (ABM)
Energy saving (UPS sleep mode)
Cold start (DC power on)
SNMP capability (optional)
USB capability (optional)

* Feature only for 100V/110V/115V models


Description:

Pure sine wave output for any critical load.

Specifications:
Tower Model (LED display) PM-321500SKE
Tower Model (LCD display) PM-321500SKC
19" Rack-mount Model (LED display) PM-321500SKER
19" Rack-mount Model (LCD display) PM-321500SKCR
INPUT

 

Capacity 1500VA
Voltage +/-25% at line input, single phase
Frequency 50 or 60Hz +/-5Hz (auto sensing)
OUTPUT Voltage
(on battery)
Pure sine wave at +/-5% of nominal, -10% of nominal after low battery warning
Frequency
(on battery)
50 or 60Hz +/-0.5%
Voltage Regulation (AVR) AVR automatically increase output voltage 15% above input voltage if -9% to -25% of nominal.
AVR decrease output voltage 15% below input voltage if +9% to +25% of nominal
PROTECTION
& FILTERING
Spike Protection 320 Joules, 2ms
Unit Input Fuse for 110V models Except 3000A, breaker for 220V models Except 1000A
EMI/RFI filter 10dB at 0.15MHz, 50 dB at 30MHz
Overload Protection UPS automatic shutdown if overload exceeds 110% of nominal at 20 seconds and 125% at 5 seconds.
Transfer Time 2/4 milliseconds (typical), including detection time
Short Circuit UPS output cut off immediately or input fuse (or breaker) protection
BATTERY Type Hot swappable, sealed, maintenance-free lead acid, with 3-6 years lifetime
Typical Recharge Time 4 hours (to 90% of full capacity)
Protection Automatic self-test & discharge protection, Replace battery indicator
Back up Time
(one PC and one 15" monitor)
90 min
Net Weight Kg
(lbs)
Tower 25.0 (55.0 lb)
19" Rack-mount 26.1 (57.4 lb)
DIMENSION
W x D x H (mm)
Tower 170 x 450 x 226 (6.7" x 17.7" x 8.9")
19" Rack-mount 483 x 381 x 130 (19.0" x 15.0" x 5.1")
LCD Indicators Status Indicate line, bypass, inv, backup, fault, bat capacity, load capacity, I/P frequency, O/P voltage, O/P frequency, inside temperature, fault status, load
INTERFACE RS232 Detect battery low, Schedule UPS on/off, AC input/output power status display.
Dry contact Sends AC fail and battery low signals, and receives shutdown signal from computer.
Option Novell, SNMP, Windows NT, Windows 95/98/2000/ME
ALARM Battery Back-up Slow beeping sound (about 0.25Hz)
Battery Low Rapid beeping sound (about 1.00Hz)
Overload Continuously beeping sound
ENVIRONMENT Ambient Operation 3,500 meters max, elevation. 0-95% humidity non-condensing, 0-40 deg
Audible Noise <45dBA (1 meter from surface)
Storage Condition 15,000 meter max. elevation


Certificate
On-line Catalog

Character:
Multiple Microprocessor design base
Detachable control panel with LED
Unity input power factor and wide input range
Robust design with output transformer
True sine-wave double conversion on-line UPS
DC start and automatic self-diagnostic function
Capacity of battery unlimited and alarm silent
RS232 communication port and built-in SNMP slot
High efficiency design to save electricity
Low heat dissipation in long term operation
Designed to operate under harsh environment
Enhanced protections against lighting surges, disturbances etc..


Description:
3 phase in 1 phase out online UPS.
Advanced Power Protection for Enterprise Network.


Specifications:
MODEL PM-8010SS-LED
CAPACITY Capacity 10KVA / 7000W
INPUT Nominal Voltage 3P4W 380Vac
Voltage Range 304~478Vac +/- 3Vac
Frequency 50Hz or 60Hz +/- 8%
Power Factor >= 0.95
OUTPUT Voltage 220Vac +/- 1% (230V or 240V re-settable via LCD panel)
Frequency 50Hz or 60Hz +/- 8% Synchronized (Line Mode)                           50Hz or 60Hz +/-0.5% (Battery Mode)
Wave-form True Sine wave
Distortion (Tower) =<2% THD (Linear Load), =<6% THD (Non-Linear Load)
Distortion (Rack) N/A
Crest Ratio 3:1
BATTERY Type Maintenance free sealed lead-acid battery
Capacity N/A
Charger (Option) N/A
Built-In Charger 4.2A
Back-up (Full/Half load) Depending on the capacity of external batteries
BYPASS Automatic Overload and UPS failure
Transfer Time 0 ms( AC to DC & Inverter to Bypass)
Display               (LED Series) LED AC input (Green), Bypass (Yellow), Battery Low (Yellow), Inverter (Green), Load% (5 LEDs), Battery % (5 LEDs),       Fault (Red)
AUDIBLE ALARM Battery Mode Beeping every 4 seconds
Battery Low Beeping every seconds
Overload Beeping twice per second
Fault Beeping Continuously
INTERFACE RS-232 Interface UPSilon 2000 monitoring software
SNMP For Net Agent II (Option) with SNMP manager and Web browser
NETWORK Surge Protection RJ45 I/O port available for 10 base-T network or Fax / Modem
ENVIRONMENT Temperature 0-40 degree C; 32-104 degree F
Humidity 20-90% non-condensing
Acoustic Noise Less than 55dBA (at 1 meter)
NET WEIGHT w/o battery 38.5kgs
w/ battery N/A
Dimension (WxHxD) mm Tower Case 260 x 717 x 570
Rack Case (2U) N/A