HOME > Products > UPS > Heaven Series (Rack Mount) 0.6K~3.0KVA > PM-323000SKER

無標題文件


Certificate
On-line Catalog
Back Panel
Character:
Line interactive design
Boost and buck AVR
Hot swappable battery replacement by users
Overload, on-line, battery status LED or LCD display
Fully digitized microprocessor controlled
Smart RS-232 communication port
Lightning and surge protection
Short circuit and overload protection
50/60Hz frequency auto sensing
Tel/modem internet spike protection
Site wiring fault warning *
Smart power management with software
Load/Battery power meter display
Advanced battery management (ABM)
Energy saving (UPS sleep mode)
Cold start (DC power on)
SNMP capability (optional)
USB capability (optional)

* Feature only for 100V/110V/115V models


Description:
Pure sine wave output for any critical load.

Specifications:
Tower Model (LED display) PM-323000SKE (110V) PM-323000SKE (220V)
Tower Model (LCD display) PM-323000SKC (110V) PM-323000SKC (220V)
19" Rack-mount Model (LED display) N/A PM-323000SKER (220V)
19" Rack-mount Model (LCD display) N/A PM-323000SKCR (220V)
INPUT Capacity 3000VA 3000VA
Voltage +/-25% at line input, single phase
Frequency 50 or 60Hz +/-5Hz (auto sensing)
OUTPUT Voltage
(on battery)
Pure sine wave at +/-5% of nominal, -10% of nominal after low battery warning
Frequency
(on battery)
50 or 60Hz +/-0.5%
Voltage Regulation (AVR) AVR automatically increase output voltage 15% above input voltage if -9% to -25% of nominal.
AVR decrease output voltage 15% below input voltage if +9% to +25% of nominal
PROTECTION
& FILTERING
Spike Protection 320 Joules, 2ms
Unit Input Fuse for 110V models (600VA~2500VA) and 220V models (under 1250VA), breaker for 110V model (3000VA) and 220V models (above 1500VA)
EMI/RFI filter 10dB at 0.15MHz, 50 dB at 30MHz
Overload Protection UPS automatic shutdown if overload exceeds 110% of nominal at 20 seconds and 125% at 5 seconds.
Transfer Time 2/4 milliseconds (typical), including detection time
Short Circuit UPS output cut off immediately or input fuse (or breaker) protection
BATTERY Type Hot swappable, sealed, maintenance-free lead acid, with 3-6 years lifetime
Typical Recharge Time 4 hours (to 90% of full capacity)
Protection Automatic self-test & discharge protection, Replace battery indicator
Back up Time
(one PC and one 15" monitor)
240 min 140 min
Net Weight Kg
(lbs)
Tower 20.5 (45.1 lb) 19.5 (43.0 lb)
19" Rack-mount N/A 32.5 (71.5 lb)
DIMENSION
W x D x H (mm)
Tower 170 x 450 x 226 (6.7" x 17.7" x 8.9")
19" Rack-mount 483 x 381 x 130 (19.0" x 15.0" x 5.1")
LCD Indicators Status Indicate line, bypass, inv, backup, fault, bat capacity, load capacity, I/P frequency, O/P voltage, O/P frequency, inside temperature, fault status, load
INTERFACE RS232 Detect battery low, Schedule UPS on/off, AC input/output power status display.
Dry contact Sends AC fail and battery low signals, and receives shutdown signal from computer.
Option Novell, SNMP, Windows NT, Windows 95/98/2000/ME
ALARM Battery Back-up Slow beeping sound (about 0.25Hz)
Battery Low Rapid beeping sound (about 1.00Hz)
Overload Continuously beeping sound
ENVIRONMENT Ambient Operation 3,500 meters max, elevation. 0-95% humidity non-condensing, 0-40 deg
Audible Noise <45dBA (1 meter from surface)
Storage Condition 15,000 meter max. elevation