Model
Item |
PM-5000GT |
Inverter
Technology |
Conversion Mode |
Sine-wave, Current source, High frequency PWM |
Isolation Method |
Transformer-less Design * |
DC Input Data |
|
Nominal DC Voltage |
360 VDC |
Max. DC input Voltage |
500 VDC |
Working range |
120VDC~500VDC ** |
Max DC input current
(Each MPPT Tracker) |
17.65 Amp |
MPPT Range |
150 VDC ~ 450 VDC |
MPPT Tracker |
2 |
AC Output Data |
|
Nominal AC Power |
5000 |
Max. AC Power |
5300 |
Nominal AC Voltage |
AC 230V |
Output Connect Method |
1-Phase / 2-Wires(L, N, G) or 1-Phase / 3-Wires(L1, L2, G) |
AC Voltage Rang |
184~264.5Vac(Base on 230 Vac) |
Nominal AC Current |
21.7Amp |
Frequency |
50/60Hz Auto-Selection (47.5 ~ 50.2 Hz or 59.3 ~ 60.5 Hz) |
Power Factor |
>0.99 with nominal AC current |
Current Distortion |
Total Harmonic current : Less than 5%
Single Harmonic current : Less than 3% |
Efficiency Data |
|
Max. efficiency |
>96% |
Euro efficiency |
>94% |
CEC efficiency |
>94% |
Environmental |
|
Operating Temperature |
-25 °C ~ + 50 °C |
-13 °F ~ 122 °F |
Humidity |
0 to 90%(Without condensation) |
Altitude |
0 ~ 2000 M / 0 ~ 6600 ft |
Mechanical |
|
Dimensions
(H x W x D in mm ) |
455 x 510 x 170 |
Weight (Kgs / Lbs) |
28 / 62 |
Protection Class |
IP65, outdoor |
Cooling |
Free Convection |
AC Connector |
Terminal |
DC Connector |
Multi-Contact |
Communication |
|
Communication Interface |
RS232 |
USB, RS485, Dry contact, TCP/IP |
Front Panel |
|
LCD |
Boost input Voltage/Boost input Current/Boost input Power/AC output Voltage /AC output frequency/AC output current /AC output power/AC Energy yield/Inner Temperature/Heat sink Temperature /Status message/ Error message |
LED |
Leakage current fault or DC input isolation fault |
Spec. of Utility is not matches with the Utility specifications of the inverter |
Solar Cell power is greater or smaller than sleep power |
Key Pad |
UP key/ Down key/ Function key/ Enter key |
Protection |
|
Utility |
Over/under Voltage, Over/under Frequency,
Ground fault, DC Isolation fault |
Islanding operation detection |
Passive : Voltage phase jump detection
Active : Reactive power control |
Over Temperature |
reduced output power |
Certification |
|
Safety |
VDE 0126-1-1, EN50178, IEC62103 |
UL1741, IEEE1547 |
EMI/EMC |
EN 6 1000-6-1, EN 6 1000-6-2, EN 6 1000-6-3, EN 6 1000-6-4 |