Character:
Multiple microprocessor design base.
Compatible with both linear & non-linear load.
Stronger charger to support batteries of 600AH up.
24 hours operation on the inverter.
DC start and automatic self-diagnostic function.
THD less than 3%.
High efficiency design to save electricity.
Low heat dissipation in long time operation.
Design to operate under harsh environment.
3U 19″ Rack Mount or WALL Mounted design.
DC priority or AC priority selectable.
Support solar panel.
Description:
Solar Inverter with LCD Display~
PURE SINE WAVE Inverter with DC battery charger and Solar charge controller.
Connect directly with Solar system.
Smart; powerful and successful.
Specifications:
Model | PM-1600SLU-24 | |||
Capacity | VA / Watt | 2.4KVA / 1600W | ||
Input | Nominal Voltage | 220Vac ; 110Vac | ||
Voltage Range | Acceptable Voltage Range | 120-280Vac ; 60-140Vac | ||
Frequency | 50Hz / 60Hz ( 45Hz – 70Hz) | |||
Line Low Transfer | 120VAC ± 2% ; 60VAC ± 2% | |||
Line Low Return | 130VAC ± 2% ; 65VAC ± 2% | |||
Line High Transfer | 280VAC ± 2% ; 140VAC ± 2% | |||
Line High Return | 260VAC ± 2% ; 130VAC ± 2% | |||
Output | Voltage | 200 / 220 / 230 / 240Vac (re-settable via LCD panel) 100 / 110 / 115 / 120Vac (re-settable via LCD panel) |
||
Voltage Regulation (Batt. Mode) | < 3% RMS for entire battery voltage range | |||
Frequency | 50Hz or 60Hz | |||
Frequency Regulation (Batt. Mode) | ± 0.1Hz | |||
Power Factor | 0.67 | |||
Waveform | Pure Sinewave | |||
Effiecincy | > 80% | |||
Overload Protection | Line Mode | Circuit Breaker | ||
Battery Mode | 110% ~ 150% for 30 sec. ; >150% for 200ms | |||
Transfer Time | Typical | < 8 ms. | ||
Battery | Battery Voltage | 24Vdc (20~32) | ||
Backup Time (at full load) | long time available | |||
Max. Charging Current (3 steps selectable) |
60 / 80 / 100 Amp | |||
Solar Charge | Battery Voltage | 24V | ||
Charge Voltage | 27.7V | |||
Solar Maximum Peak Voltage | 50.0V | |||
Solar Charge Working Voltage | 24.0V | |||
Maximum Charging Current | 50A | |||
Polarity Protect | YES | |||
Back Flow Protect | YES | |||
Display LCD | LCD | UPS status; I/P&O/P Voltage Frequency; Load%; Battery Voltage & %; Charge current; Temperature; Model |
||
LED | Normal (Green); Warning (Yellow); Fault (Red) | |||
Audible Alarm |
Battery Mode | Beeping every 4 seconds | ||
Low Battery | Beeping every second | |||
UPS Fault | Beeping Continuously | |||
Overload | Beeping twice per second | |||
Environment | Operation Temperature | 0-40 °C ; 32-104 °F | ||
Relative Humidity | 0-95% non-dondensing | |||
Audible Noise | Less than 55dBA (at 1M) | |||
Physical | Net Weigh (Kgs) | 21 | ||
(WxHxD) mm Black Case | 298 x 450 x 150 | |||
(WxHxD) mm Rack Mount | 440 x 132 x 360 | |||
(WxHxD) mm Wall Mounted | 298 x 450 x 190 |