Character:
Line interactive design
Easy LCD display
Provide boost and buck AVR to stabilize input voltage
Provide lightning; surge; overload; and short-circuit protection
Built-in CCCV battery charger and battery over drain protection
No load auto shutdown (Dip switch set up)
Auto restart when AC recovery
Buzzer alarm auto reset (Dip switch set up)
Cold start function (DC power on)
Tel/Modem/Fax/Internet surge suppression
Optional bundles software automatically save your valuable files before auto shutdown
Microprocessor design for true RS-232 (optional)
Available to extend back-up time (to add extra external battery bank)
Description:
The most suitable and the best Quality Protection for Small Servers; and Workstations & PCs.
Specifications:
MODEL | PM-5330AP | |
Capacity | 3000VA / 1800W | |
Input | Voltage | 110/115/120VAC or 220/230/240VAC |
Voltage Range | 86VAC~144VAC or 172VAC ~288VAC (+/-25%) | |
Frequency | 47Hz~53Hz or 57Hz~63Hz | |
Output | Voltage Regulation (Battery Mode) |
110/115/120VAC or 220/230/240VAC (+/-10%) |
Frequency | 50Hz or 60Hz +/-1Hz | |
Waveform | Simulated Sinewave | |
Transfer Time | < 6ms (Typical) | |
Outlet | German / NEMA 5-15R | 6 / 8 |
Battery | Battery Type | 12V/9AH * 4pcs |
Recharge Time | 5Hrs to 90% after complete discharge | |
User’s Replacement | Yes | |
Battery Protection | Over discharge protection & Short circuit protection by fuse | |
Advanced Battery Management | Yes | |
Battery Back-up Time | It depends on connection loads | |
Function | Display (LCD) | LCD display for AC normal; Back-up; AVR protection; Load and Battery level; Overload and UPS cut off |
Alarm | Buzzer on for Back-up mode; Battery low; Overload | |
Output Short Protection | AC fuse and Electronic circuit (Line mode); Electronic circuit (Back-up mode) |
|
Communication Port | Shutdown software for Windows 95/98/NT/2000/ME/XP/Vista | |
Modem/Phone Protection | RJ-11 / RJ-45 | |
Lightning/Surge Protection | 240joules | |
AVR (Auto. Voltage Regulation) |
Boost / Buck | |
DC Start Function | Yes | |
Auto. Restart UPS | Yes | |
Over/Under Voltage Protection | Yes | |
Environment | Safety Standard | CE (EN50091-1; EN62040-1-1) |
EMC Standard | FCC Part 15 Class B;CE (EN50091-2; EN55011; EN61000-3-2; EN61000-3-3) |
|
RoHS | Meets RoHS standard | |
Operating Temperature | 0 ~ 40 °C | |
Relative Humidity | 0 ~ 95%; non-condensing | |
Audible Noise | < 40dB at 1M | |
Physical | Dimension (D*W*H) | 390 * 182 * 285mm |
Net Weight | 28Kgs | |
Design; Manufacture; Services | ISO 9001-2000 | |
Warranty | 1 year |