Character:
Multiple Microprocessor design base
Detachable control panel with LCD
Unity input power factor and wide input range
Robust design with output transformer
True sine-wave double conversion on-line UPS
DC start and automatic self-diagnostic function
Capacity of battery unlimited and alarm silent
RS232 communication port and built-in SNMP slot
High efficiency design to save electricity
Low heat dissipation in long term operation
Designed to operate under harsh environment
Enhanced protections against lighting surges, disturbances etc..
Description:
Advanced Power Protection for Enterprise Network.
Specifications:
MODEL | PM-6010MS-LED | PM-6010MS-LCD | |
CAPACITY | Capacity | 10KVA / 7000W | |
INPUT | Nominal Voltage | 1P2W 220Vac | |
Voltage Range | 176~276Vac +/- 3Vac | ||
Frequency | 50Hz or 60Hz +/- 8% | ||
Power Factor | >= 0.98 | ||
OUTPUT | Voltage | 220Vac +/- 1% (230V or 240V re-settable via LCD panel) | |
Frequency | 50Hz or 60Hz +/- 8% Synchronized (Line Mode) 50Hz or 60Hz +/-0.5% (Battery Mode) |
||
Wave-form | True Sine wave | ||
Distortion (Tower) | =<2% THD (Linear Load), =<6% THD (Non-Linear Load) | ||
Distortion (Rack) | N/A | ||
Crest Ratio | 3:1 | ||
BATTERY | Type | Maintenance free sealed lead-acid battery | |
Capacity | 12V / 9Ah * 20pcs | ||
Charger (Option) | Built-In 4.2A Charger | ||
Built-In Charger | 2A | ||
Back-up (Full/Half load) | 5 min. | ||
BYPASS | Automatic | Overload and UPS failure | |
Transfer Time | 0 ms( AC to DC & Inverter to Bypass) | ||
INDICATOR UPSERVER (LCD Series) | LCD | UPS status, I/P&O/P Voltage& Frequency, Load %,Battery Voltage, Temperature, Event Log | |
LED | Normal (Green), Warning (Yellow), Fault (Red) | ||
Display (LED Series) | LED | AC input (Green), Bypass (Yellow), Battery Low (Yellow), Inverter (Green), Load% (5 LEDs), Battery % (5 LEDs),Fault (Red) | |
AUDIBLE ALARM | Battery Mode | Beeping every 4 seconds | |
Battery Low | Beeping every seconds | ||
Overload | Beeping twice per second | ||
Fault | Beeping Continuously | ||
INTERFACE | RS-232 Interface | UPSilon 2000 monitoring software | |
SNMP | For Net Agent II (Option) with SNMP manager and Web browser | ||
NETWORK | Surge Protection | RJ45 I/O port available for 10 base-T network or Fax / Modem | |
ENVIRONMENT | Temperature | 0-40 degree C; 32-104 degree F | |
Humidity | 20-90% non-condensing | ||
Acoustic Noise | Less than 55dBA (at 1 meter) | ||
NET WEIGHT | w/o battery | 93kgs | |
w/ battery | N/A | ||
Dimension (WxHxD) mm | Tower Case | 260 x 717 x 570 | |
Rack Case (2U) | N/A |